Material, defect and penetration control of seepage beneath culverts on sand with silicate-cement grout curtains
Abstract
Silica sol-cement grout reduces the conductivity of sand by three to four orders of magnitude, but the seepage beneath a grouted structure also depends on the depth and continuity of the curtain. This paper analyses steady seepage beneath an impervious culvert floor on a sand layer with a grout curtain at its upstream edge. Defects are represented by an equivalent conductivity ratio βeq = (1 - f)β + f. For a fully penetrating curtain a closed-form series model gives the discharge ratio q/q0 = 1/(1 + Π), with Π = (b/T)/(βeq Φ0), and a critical conductivity ratio for a target efficiency. A finite volume solution agrees with the conformal-mapping discharge within 0.02% after Richardson extrapolation (0.5% on the working mesh) and with the series model within 1% for βeq ≤ 0.3. The framework is applied to nine published mixes with β = 1.6 × 10⁻⁴ to 2.0 × 10⁻³ at 3 to 28 days. Partial curtains are penetration-controlled from 3 days, with q/q0 = 0.841, 0.679 and 0.500 for d/T = 0.25, 0.5 and 0.75. An intact fully penetrating curtain reaches an efficiency of 0.969 at 3 days and 0.993 at 28 days, but defect ratios of 0.1%, 1% and 5% reduce it to 0.935, 0.710 and 0.343. The boundary between material- and defect-controlled behaviour lies at f ≈ β, so curtain continuity controls the efficiency more than curing age.
References
- V. C. Nguyen, Q. B. Nguyen, T. T. Nguyen, and T. M. P. Nguyen, “Design of silica sol-cement grout mixes for emergency treatment of seepage in sandy foundations of hydraulic structures,” J. Water Resour. Sci. Technol., no. 73, pp. 1–10, 2022 (in Vietnamese).
- V. C. Nguyen, Q. B. Nguyen, V. T. Chu, and T. T. Nguyen, “Application of sodium silicate grouting technology to treat seepage incidents in hydraulic structures,” J. Agric. Rural Dev., pp. 37–45, Sep. 2023 (in Vietnamese).
- T. B. Le and V. C. Nguyen, “Proposed grout mix design and application orientation of silicate-cement injection in project management for seepage control in sandy foundations of hydraulic structures,” J. Mater. Constr., vol. 15, no. 1, pp. 11–18, 2025.
- E. Avcı, E. Deveci, and A. Gokce, “Effect of sodium silicate on the strength and permeability properties of ultrafine cement grouted sands,” J. Mater. Civ. Eng., vol. 33, no. 8, 2021, doi: 10.1061/(ASCE)MT.1943-5533.0003815.
- Z. Cai, W. Yang, Y. He, M. Song, G. Zuo, and W. Chen, “Reinforcement of completely weathered granite by nano-silica sol and its permeability law,” J. Zhejiang Univ. (Eng. Sci.), vol. 59, no. 12, pp. 2635–2644, 2025, doi: 10.3785/j.issn.1008-973X.2025.12.018 (in Chinese).
- Hydraulic structures - Technical requirements for construction and acceptance of grouting into soil foundations for seepage control, TCVN 14149:2024, Ministry of Science and Technology, Hanoi, Vietnam, 2024 (in Vietnamese).
- Ministry of Housing and Urban-Rural Development of the People's Republic of China, Technical Specification for Cement-Sodium Silicate Grouting in Building Engineering, JGJ/T 211-2010, Beijing, China, 2010 (in Chinese).
- C. Shi, X. Sun, S. Liu, C. Cao, L. Liu, and M. Lei, “Analysis of seepage characteristics of a foundation pit with horizontal waterproof curtain in highly permeable strata,” Water, vol. 13, no. 9, Art. no. 1303, 2021, doi: 10.3390/w13091303.
- K. Meshkabadi and Y. Zandi, “The effects of grout curtain parameters on uplift and piping phenomenon; case study: Sattarkhan Dam,” Hydrology, vol. 6, no. 3, Art. no. 71, 2019, doi: 10.3390/hydrology6030071.
- A. J. Thomas and A. Ahangar Asr, “Investigating branched cut-off wall effect on seepage using numerical modelling,” Eur. J. Comput. Mech., vol. 33, no. 3, pp. 295–328, 2024, doi: 10.13052/ejcm2642-2085.3334.
- I. Faridmehr, M. R. YazdaniPour, M. Javadi Jokar, and T. Ozbakkaloglu, “Construction and monitoring of cement/bentonite cutoff walls: Case study of Karkheh Dam, Iran,” Stud. Geotech. Mech., vol. 41, no. 4, pp. 184–199, 2019, doi: 10.2478/sgem-2019-0019.
- Y. Chen, B. Xue, S. Zhang, X. Du, and M. Shi, “Seepage characteristics analysis on earth dams considering polymer cutoff wall with construction defects,” Sustainability, vol. 14, no. 19, Art. no. 11879, 2022, doi: 10.3390/su141911879.
- J. Mei, H. Cao, G. Luo, and H. Pan, “Analytical method for groundwater seepage through and beneath a fully penetrating cut-off wall considering effects of wall permeability and thickness,” Water, vol. 14, no. 23, Art. no. 3982, 2022, doi: 10.3390/w14233982.
- A. K. Jain and L. N. Reddi, “Finite-depth seepage below flat aprons with equal end cutoffs,” J. Hydraul. Eng., vol. 137, no. 12, pp. 1659–1667, 2011, doi: 10.1061/(ASCE)HY.1943-7900.0000459.
- Hydraulic concrete mixture and hydraulic concrete - Test methods, TCVN 8219:2009, Hanoi, Vietnam, 2009 (in Vietnamese).
- Hydraulic structures - Calculation of underground seepage contours, TCVN 9143:2012, Hanoi, Vietnam, 2012 (in Vietnamese).